LEGACY CONTENT
This article refers to legacy products, components or features. Therefore, the content in this article is offered "as is" and will no longer be updated. This content does not infer that the product, component or feature is supported, or that the product, component or feature will continue to function as described herein.

Introduction

When executing asynchronous / synchronous IPC processes using K2 blackpearl 0807 (4.8210.2.370) the parent processes starts, and completes the client event but does not continue on to the IPC event. An “Invalid archive type” error occurs when trying to access the IPC events.

Error Scenario Steps

Note: The steps below describe one scenario under which this error may occur. The steps below are simplified and not all the steps will be shown or described.
  1. Create and start an asynchronous / synchronous IPC process.
  2. Start the K2 Server.
  3. An “Invalid archive type” error occurs when trying to access the IPC events.

Error Messages

The following error message relates to this issue:
  • Attempted to read or write protected memory. This is often an indication that other memory is corrupt.

Error Resolution

This Hotfix is contained within the latest K2 blackpearl 0807 Update. Install the update package to resolve the error.

The latest K2 blackpearl 0807 Update is available as an independent installation package which can be found here: https://portal.k2.com/downloads/bp/default.aspx