Code Fix: An error occurs when attempting to edit a K2 Workflow

  • 16 February 2021
  • 0 replies
  • 12 views

 

Code Fix: An error occurs when attempting to edit a K2 Workflow

KB003116

PRODUCT
K2 Five 5.2
K2 Five (5.2) Fix Pack 33

 

Issue Description

When loading a K2 Workflow using the KPRX file to edit the workflow, an error occurs.

Error Message

The following error occurs: “500 internal Server error”

Cause

This was caused by an empty repetitions field in the reminders tab of a user task.

Resolution

  1. Ensure you have K2 Five (5.2) installed.
  2. Download the K2 Five (5.2) FP33 from K2 Partner and Customer Portal.
  3. Install the K2 Five (5.2) FP33 to apply the fix.
  4. Refresh the browser.
  5. Re-load the workflow.

 


0 replies

Be the first to reply!