Code Fix: K2 Server ceases to function correctly when LIM API is used to change process version number
Introduction
Error Scenario
The error can be reproduced by following the steps below:
- Deploy a process twice to create two different versions of the same process
- Start and stop instances of the two processes
- Use the API to change the version number of the process instance
Error Messages
The following error message applies to this article:
- 15101 Error occurred, ERROR: 24143 Unable to Forward Cluster Message, server entry 0 not found
Error Resolution
This Hotfix is contained within the latest K2 blackpearl 0807 Update. Install the update package to resolve the error.
The latest K2 blackpearl 0807 Update is available as an independent installation package which can be found here: https://portal.k2.com/downloads/bp/default.aspx